18色譜柱(250mm×4.6 mm,5 μm),以水/三氟乙酸混合溶液(1 000∶0.5)為流動相A,甲醇-乙腈-水-三氟乙酸混合溶液(600∶350∶50∶0.35)為流動相B,流動相A與流動相B比例為45∶55,體積流量1.0 mL/min,檢測波長為254 nm,柱溫40℃。結(jié)果 在上述色譜條件下,氫溴酸沃替西汀與其同分異構(gòu)體分離良好。試驗專屬性、線性、精密度、準(zhǔn)確性良好,所使用濾膜對結(jié)果測定無干擾。結(jié)論 該方法準(zhǔn)確、可靠、耐用性好,可為氫溴酸沃替西汀片的質(zhì)量控制提供參考依據(jù)。;Objective To establish a method for determining the dissolution of Vortioxetine hydrobromide tablets and analyze the dissolution behavior in vitro.Methods To establish HPLC determination method for the dissolution of Vortioxetine hydrobromide tablets and verify the specificity, linearity, precision, accuracy, membrane filter interference. Chromatographic separation was achieved on an Octa Decyl Silyl column (Waters Symmetry® C18, 150 mm×4.6 mm ID, 5 μm particle); Mobile phase A:water - trifluoroacetic acid (1 000:0.5), mobile phase B:methyl alcohol - acetonitrile - water - trifluoroacetic acid (600:350:50:0.35). The flow rate was 1.0 mL/min and the detection wavelength was 254 nm, column temperature was 40℃. Results Under the chromatographic conditions, the resolution of Vortioxetine hydrobromide and structural isomer was great, the specificity, linearity, precision, accuracy of the method was good, the membrane filter didn't affect the results, Conclusion The method is accurate, reliable and durable, and can be used in the quality control of Vortioxetine hydrobromide tablets."/>